UTD –C –ia IICT(2—5)electric floating liquid position transducer is explosion equipment which can protect measured liquid safety continued .The equipment is used for the location which is full of dangerous indencive and explosive gas ;The equipment is fit for industrial factory which measure liquid position and control the liquid kettle in the manufactory process such as petroleum and chemical plant .The equipment outputs standard DC 4—20mA signal which can be sended in the long distance and can be used on layout with other equipment in order to achieve liquid itself being controlled and achieve two liquid interfaces controlling
This equipment has three features: 1, transmission credible
2,installing agility 3,meterage widely
OPERATION THEORY:
According to the liquid positon changed brings flotage changed so that torsional cannulation’s loading increase or decrease .The increasing or dereasing quantity is direct ratio with liquid proportion. Torsional cannulation rotates by flotage influenting in order to drive the transformation equipment ‘s rotor bringing synchronous angle moving and bringing voltage variable with rotor direct ratio .The voltage variable is transferred and magnified into DC4~20mA standard current signal
MAIN TECNECH PARAMETER:
PRECISION LEVEL : 0.5 ;1;1.5;2.5
OUTPUT SIGNAL : 4~20mA,DC
LOADING ABILITY : MAX 350 OHM
TRANSFERING STYLE : TWO WIRES
ENVIRONMENT TEMPERATURE:--25~ 55 CENTIGRADE
CORRESPONDINGLY TEMPERATURE: <85%
MEDIUM PROPORTION: >0.4—1.4
MEDIUM PROPORTION DIFFERENCE: >0.2
MEDIUM TEMPERATURRE : <120 CENTIGRADE
MEDIUM WORKING PRESSURE : 4Mpa
POWER VOLTAGE : 24V.DC+_5%
EXPLOSION—PROOF : ia IICT(2~5)